Type 1+2 AC Surge Protective Device
Choose Your Type 1+2 AC SPD
Additional information
| Uc | 275v |
|---|---|
| In | 30kA |
| Imax | 60kA |
| Iimp | 4.5kA |
Additional information
| Uc | 275v |
|---|---|
| In | 20kA |
| Imax | 50kA |
| Iimp | 12.5kA, 7kA |
Additional information
| Uc | 275v |
|---|---|
| In | 20kA |
| Imax | 50kA |
| Iimp | 12.5kA |
Additional information
| In | 30kA |
|---|---|
| Imax | 60kA |
| Iimp | 12.5kA |
Compare Type 1+2 AC SPDs
A quick side-by-side view of the four products. Enquire about any model without leaving this page.
| Model | Uc | Iimp | In / Imax | Up | Structure | Key Difference | Enquiry |
|---|---|---|---|---|---|---|---|
| TRS5-B+CSeries | 275 V AC | 7 / 12.5 kASeparate versions | 20 / 50 kA | ≤1.3 kV | MOV Pluggable |
7 kA or 12.5 kA Iimp versions; pluggable MOV construction. | Get a Quote → |
| TRS5-B+CDual Series | 275 V AC | 12.5 kA | 20 / 50 kA | ≤1.3 kV | MOV Pluggable |
12.5 kA Iimp; 2P and 4P formats shown in the Dual Series catalogue. | Get a Quote → |
| TRS8-B+C | 275 V AC | 12.5 kA | 30 / 60 kA | ≤1.5 kV | MOV + GDT | MOV + GDT construction with 12.5 kA Iimp and 30 / 60 kA In / Imax. | Get a Quote → |
| TRS30B+C | 275 V AC | 4.5 kA | 30 / 60 kA | ≤1.5 kV | MOV Pluggable |
Pluggable MOV construction with 4.5 kA Iimp and 30 / 60 kA In / Imax. | Get a Quote → |
Values shown are for the catalogue versions with Un 230 V AC and Uc 275 V AC. TRS5 Series has separate 7 kA and 12.5 kA Iimp versions; these are not a combined rating. Iimp uses the 10/350 μs waveform, while In and Imax use 8/20 μs. Select the version and circuit configuration that match your specification.
Have a preferred model—or still comparing?
Request pricing and datasheets for your preferred model. Tell us the quantity and application you have in mind.
Enquire directly
Request a Type 1+2 SPD Quotation
Tell us which model you are considering and your quantity. You can also ask for datasheets, configuration details or OEM options.
Not sure which model? Describe the application or share the specification you have. Technical details are optional at this stage.
- Pricing and model availability
- Model-specific datasheets and documents
- Distributor, project and OEM enquiries
THOR Electric
Technical Documents and Supply Support
Model-specific documents
Request datasheets and circuit diagrams. Include the model name in your enquiry.
Order requirements
Confirm the model, ratings, quantity and required documents together with your quotation.
Distributor & OEM enquiries
Include branding, packaging and certification requirements when discussing your order.
Before you order
Type 1+2 AC SPD FAQs
How does a Type 1+2 SPD differ from separate Type 1 and Type 2 SPDs?
A Type 1+2 SPD combines both test classifications in one device. Separate units require a coordinated arrangement. Compare the installation layout, specified ratings and coordination instructions for the actual models.
Where should a Type 1+2 SPD be installed?
Typically at the incoming supply or main distribution board where the design requires Type 1 and Type 2 performance together. Confirm local installation requirements, earthing, backup protection and the selected model’s wiring instructions.
What Iimp rating should I choose?
Use the project’s lightning protection requirements and applicable installation rules. Check the declared rating for each relevant protection path. Higher Imax does not compensate for insufficient Iimp.
Can Type 1+2 SPDs be used in three-phase systems?
Yes, when the selected model has suitable ratings and a suitable configuration. Confirm neutral availability, earthing and protection modes using the circuit diagram. Do not select by pole count alone.
How do I choose Uc?
Select Uc for the maximum continuous voltage across each protection mode, considering the supply and earthing arrangement. Review temporary overvoltage behaviour and Up. Do not select solely from the line-to-line system voltage.
Do I still need downstream Type 2 protection?
Possibly. An incoming Type 1+2 SPD does not automatically cover every downstream location. Cable distance, equipment requirements and the manufacturer’s coordination instructions determine whether additional protection is needed. Include your layout with the enquiry if you want it reviewed.
What information does THOR need to recommend a model?
Provide system voltage, phase and neutral arrangement, earthing, installation location and any specified Iimp, In or Up requirements. Include the required standard or certification, quantity and wiring diagram when available.