AC TRS5 B+C

Type 1+2 AC Surge Protective Device TRS5 B+C

Main Features

  • Lightning impulse current(10/350μs) In: 7kA/12.5kA
  • Nominal discharge current (8/20μs) In: 20kA
  • Maximum discharge current (8/20μs) Imax: 50kA
  • Network Systems: TN-S, TT, TN-C-S
  • Mode of Protection: L-PE, N-PE
  • IEC/EN Category: Type 1+2 / Class I+II / Class B+C
  • Protective Elements: High Energy MOV
  • Housing: Pluggable design
  • Application: Sub-Distribution Board
  • Compliance: EN 61643-11:2012, IEC 61643-11:2011

CE certification ISO certification RoHS certification

The TRS5-B+C is a modular Type 1+2 surge protective device designed for applications requiring easy maintenance and fast module replacement.
Built with high-quality MOV components, the pluggable design enables technicians to replace protective cartridges without disconnecting wiring, reducing downtime and simplifying long-term system upkeep.

With a 7 kA (10/350 μs) impulse rating for lightning current and 50 kA maximum discharge capability, the TRS5 series offers dependable protection for residential and commercial power systems.
Its ≤1.3 kV voltage protection level efficiently limits transient overvoltages to safeguard sensitive downstream loads.

The device includes a clear red fault indicator and supports potential-free remote signaling, enhancing system visibility. Compact and easy to install on a 35 mm DIN rail, the TRS5-B+C is suitable for multi-unit buildings, commercial distribution panels, and installations with routine service requirements.

Applications

Residential and commercial sub-distribution boards
Buildings without external LPS or with moderate lightning exposure
Installations prioritizing quick replacement through pluggable cartridges
Electrical systems requiring simplified maintenance
Distribution panels for offices, retail locations, and small industrial units

Model TRS5-B+C
Nominal volatge (Un) 230V AC
Maximum operating voltage (Uc) 275V AC
Lightning impulse current(10/350μs) (limp) 12,5kA
Nominal discharge current(8/20μs) (In) 20kA
Maximum discharge current(8/20μs) (Imax) 50kA
Voltage protection level (Up) ≤1,3kV
Response time (ta) <25ns
Cross-section of connected conductors solid(min/max) 16mm²/35mm²
Cross-section of connected conductors stranded(min/max) 16mm²/35mm²
Fault indication red indication field
Remote indication potential-free change-over contact
remote indication contacts 250V/0,5A AC,250V/0,1A DC
Cross-section of remote indication conductors 1,5mm²
Degree of protection IP20
Range of operating temperatures(min/max) -40℃~+70℃
Humidity range 5%~95%
Mounting DIN rail 35 mm
According to standard EN61643-11:2012,IEC 61643-11:2011/T1+T2
Remarks Other Uc can be customized. (420VAC,385VAC,320VAC,etc.)

TRS5 Dimension

TRS5 Circuit diagram

Installation Instruction AC SPD TRS5Installation Instruction AC SPD TRS5

Related Products

Type 2 DC Surge Protective Device TRS8
PV TRS8

Type 1+2 PV Surge Protective Device TRS8 1500v

Uocstc

1000v, 1250v

Ucpv

1200v, 1500

Iimp

5kA, 7kA

THOR TRSW-N coaxial surge protector with N-Male to N-Female connectors and a grounding lug, designed for 50 ohm RF lightning protection.
TRSW-N N/M to N/F

TRSW-N N-Type Coaxial Surge Arrester 50 Ohm Male to Female

Z0

50 Ohm

IL

≤0.3dB

Freq.

DC-2.5GHz

VSWR

<1.2

Front view of Thor TRS3-C40, a DC surge protective device.
DC TRS3-C40

Type 2 DC Surge Protective Device TRS3-C40

Uocstc

110v, 24v, 48v, 75v

Ucpv

180v, 36v, 65v, 80v

Front view of Thor TRS30 B+C, a Type 1+2 AC surge protective device.
TRS30 B+C

Type 1+2 AC Surge Protective Device TRS30 B+C

Uc

275v

In

30kA

Imax

60kA

Iimp

4.5kA

Scroll to Top