PV TRS8

Type 1+2 PV Surge Protective Device TRS8 1500v

Main Features

  • Lightning impulse current(10/350μs) limp: 5kA/7kA
  • Nominal discharge current (8/20μs) In: 20kA
  • Maximum discharge current (8/20μs) Imax: 40kA
  • Network Systems: (+)-PE, (-)-PE, (+)-(-)
  • IEC/EN Category: Type 1+2 / Class I+II / Class B+C
  • Protective Elements: High Energy MOV
  • Housing: Pluggable design
  • Application: String box, Inverter
  • Compliance: EN 61643-31:2012, IEC 61643-31:2011

CE certification ISO certification RoHS certification TUV certification

The TRS8-DC1500 is a high-performance Type 1+2 DC surge protective device engineered for modern photovoltaic (PV) power systems operating up to 1500 VDC.
Combining MOV and GDT hybrid protection technology, it delivers strong lightning-current handling capability along with a stable clamping response, making it suitable for both rooftop PV installations and large-scale solar plants.

This device is designed to withstand demanding electrical environments where both direct lightning impulses and switching surges can pose risks to PV strings, inverters, and DC distribution equipment.
Its integrated visual fault indicator provides clear status feedback, while optional potential-free remote signaling contacts support system-wide monitoring and automated fault reporting.

Built for long-term reliability, the TRS8-DC1500 performs effectively across a wide temperature range and maintains consistent surge protection even under high DC voltage stress.
The compact housing and DIN-rail mounting structure ensure easy installation inside combiner boxes, inverter cabinets, and DC control panels.

Applications

High-voltage photovoltaic systems operating up to 1500 VDC

Utility-scale solar farms requiring Type 1+2 combined lightning and surge protection

PV combiner boxes, inverter DC inputs, and DC distribution enclosures

Installations exposed to frequent lightning activity or harsh outdoor environments

Systems requiring visual fault indication and optional remote monitoring

Projects that demand a hybrid MOV+GDT device for enhanced surge durability

Parameter/Type TRS8-DC1500
Max. PV Operating Voltage Ucpv 1500V DC
Lightning impulse current(10/350µs) Imp 5kA
Nominal discharge current (8/20µs) In 20kA
Maximum discharge current (8/20µs) Imax 40kA
Voltage protection level mode +/PE, -/PE Up ≤5.2kV
Short-circuit current rating Iscpv 10kA
Response time ta < 25ns
Cross-section of connected conductors solid(min/max) 16mm²/35mm²
Cross-section of connected conductors stranded(min/max) 16mm²/35mm²
Fault indication red indication field
Remote indication potential-free change-over contact
Remote indication contacts 250V/0.5A AC, 250V/0.1A DC
Cross-section of remote indication conductors 1.5mm²
Degree of protection IP20
Range of operating temperatures (min/max) -40℃~+85℃
Humidity range 5%~95%
Mounting DIN rail 35 mm
According to standard EN61643-31:2012, IEC61643-31:2011/T1+T2
Remarks Other Ucpv can be customized.(1200VDC, 1500VDC, etc.)

TRS8 Dimension

TRS8 Circuit Diagram

Installation Instruction AC SPD TRS8

Related Products

Type 2 DC Surge Protective Device TRS8
PV TRS8

Type 1+2 PV Surge Protective Device TRS8 1500v

Uocstc

1000v, 1250v

Ucpv

1200v, 1500

Iimp

5kA, 7kA

THOR TRSW-N coaxial surge protector with N-Male to N-Female connectors and a grounding lug, designed for 50 ohm RF lightning protection.
TRSW-N N/M to N/F

TRSW-N N-Type Coaxial Surge Arrester 50 Ohm Male to Female

Z0

50 Ohm

IL

≤0.3dB

Freq.

DC-2.5GHz

VSWR

<1.2

Front view of Thor TRS3-C40, a DC surge protective device.
DC TRS3-C40

Type 2 DC Surge Protective Device TRS3-C40

Uocstc

110v, 24v, 48v, 75v

Ucpv

180v, 36v, 65v, 80v

Front view of Thor TRS30 B+C, a Type 1+2 AC surge protective device.
TRS30 B+C

Type 1+2 AC Surge Protective Device TRS30 B+C

Uc

275v

In

30kA

Imax

60kA

Iimp

4.5kA

Scroll to Top