DC TRS2-DC

Type 2 DC Surge Protective Device TRS2-DC

Main Features

  • Nominal discharge current (8/20μs) In: 20kA
  • Maximum discharge current (8/20μs) Imax: 40kA
  • Network Systems: (DC+)-PE, (DC-)-PE
  • IEC/EN Category: Type 2 / Class II
  • Protective Elements: High Energy MOV
  • Housing: Pluggable design
  • Application: DC distribution, Industrial control panels, Telecom systems
  • Compliance: EN 61643-31:2012, IEC 61643-31:2011

CE certification ISO certification RoHS certification TUV certification

The TRS2-DC is a Type 2 DC surge protective device (SPD) designed for low-voltage DC power systems. With a maximum continuous operating voltage (Uc) of 150V DC, it provides protection against transient overvoltages caused by switching operations and indirect lightning effects.

Featuring MOV-based surge protection technology, the TRS2-DC delivers a nominal discharge current (In) of 20kA and a maximum discharge current (Imax) of 40kA under the 8/20μs waveform.

Its voltage protection level (Up) of ≤0.5kV helps limit transient overvoltages and protect sensitive electronic components in DC distribution and industrial control systems.

The compact pluggable design allows for convenient module replacement and maintenance, while standard 35mm DIN rail mounting simplifies installation within electrical cabinets and equipment enclosures.

A visual fault indicator allows users to check the operating status of the SPD. Optional potential-free remote signaling contacts enable integration with equipment monitoring systems.

With an operating temperature range of -40°C to +70°C and an IP20 protection rating, the TRS2-DC is suitable for installation inside industrial electrical cabinets and DC distribution panels.

Applications

DC auxiliary power circuits in EV charging equipment and energy storage systems (ESS).
DC power supply protection in telecommunications infrastructure.
Industrial automation and control panels.
Low-voltage DC distribution cabinets.
Sensitive electronic equipment requiring a low voltage protection level.

 

Parameter/Type TRS2-DC
Maximum continuous operating voltage Uc 150V DC
Max. PV Operating Voltage Ucpv
Nominal discharge current (8/20µs) In 20kA
Maximum discharge current (8/20µs) Imax 40kA
Voltage protection level mode +/PE, -/PE Up ≤0.5kV
Short-circuit current rating Iscpv 10kA
Response time ta < 25ns
Cross-section of connected conductors solid(min/max) 16mm²/35mm²
Cross-section of connected conductors stranded(min/max) 16mm²/35mm²
Fault indication red indication field
Remote indication potential-free change-over contact
Remote indication contacts 250V/0.5A AC, 250V/0.1A DC
Cross-section of remote indication conductors 1.5mm²
Degree of protection IP20
Range of operating temperatures (min/max) -40℃~+70℃
Humidity range 5%~95%
Mounting DIN rail 35 mm
According to standard IEC 61643-11/T2

TRS2-DC Dimension

TRS3-C40 Circuit diagram

Installation Instruction AC SPD TRS3Installation Instruction AC SPD TRS3

Rotate the 3D model to inspect the surge protective device from different angles. For detailed technical specifications, electrical ratings and installation information, please refer to the other tabs.

Related Products

THOR TRS-A12 4p 12.5kA Type 1 AC surge protection device

TRS-A12 12.5kA Type 1 AC Surge Protective Device

Uc

275v, 320v, 385v, 420v

Iimp

15kA

Type 2 DC Surge Protective Device TRS8

Type 1+2 PV Surge Protective Device TRS8 1500v

Uocstc

1000v, 1250v

Ucpv

1200v, 1500

Iimp

5kA, 7kA

THOR TRSW-N coaxial surge protector with N-Male to N-Female connectors and a grounding lug, designed for 50 ohm RF lightning protection.

TRSW-N N-Type Coaxial Surge Arrester 50 Ohm Male to Female

Z0

50 Ohm

IL

≤0.3dB

Freq.

DC-2.5GHz

VSWR

<1.2

Scroll to Top