TRS-A15

Type 1 AC Surge Protective Device TRS-A15

Main Features

  • Maximum discharge current (8/20μs) Iimp: 15kA
  • Network Systems: TN-S, TT, TN-C-S
  • Mode of Protection: L-PE, N-PE
  • IEC/EN Category: Class I / Type 1
  • Protective Elements: High Energy MOV
  • Housing: Monobloc design
  • Application: Main Distribution Board
  • Compliance: EN 61643-11:2012, IEC 61643-11:2011/T1

CE certification ISO certification RoHS certification

The TRS-A Series is a Type 1 AC Surge Protective Device designed for service-entrance and main distribution boards. Using graphite-gap discharge technology, it provides high-energy lightning current handling capability and reliable protection against direct lightning strikes and severe transient overvoltages.

With a robust discharge structure, fast response, and stable performance, the TRS-A Series is suitable for residential, commercial, and industrial low-voltage power systems located in lightning-prone or surge-intensive environments.

The TRS-A15 is the entry-level model of the TRS-A Type 1 SPD series, offering 15 kA (10/350 μs) impulse current capability. It is designed for lightning protection systems with moderate exposure levels and provides reliable discharge performance for basic service-entrance protection.

With its graphite-gap discharge structure, the device efficiently handles direct lightning current while maintaining a low voltage protection level. It is well-suited for smaller buildings, residential distribution boards, and facilities where lightning density is relatively low to medium.

Applications

Residential buildings without external LPS
Basic incoming power protection
Low-to-medium lightning risk areas
Small commercial distribution boards

Model TRS-A15 TRS-A25 TRS-A50
Nominal volatge(Un) 230 V AC
Maximum operating voltage(Uc) 275 V AC
Lightning impulse current (10/350 μs)(Iimp) 15 kA 25 kA 50 kA
Voltage protection level(Up) ≤ 2,0 kV ≤ 2,2 kV ≤ 2,5 kV
Insulation resistance group > 100 mΩ
Response time <100ns
Cross-section of connected conductors solid (min/max) 16 mm2 / 35 mm2
Cross-section of connected conductors stranded (min/max) 16 mm2 / 35 mm2
Fault indication
Degree of protection IP20
Range of operating temperatures (min/max) -40℃~+70℃
Humidity range 5%~95%
Mounting DIN rail 35 mm
According to standard EN 61643-11:2012, IEC 61643-11:2011 / T1
Remarks Other Uc can be customized.(420V AC, 385V AC, 320V AC, etc.)

TRSA-Dimension

TRS-A Circuit diagram

Installation-Instruction-AC-SPD-TRS-A Installation-Instruction-AC-SPD-TRS-A

Rotate the 3D model to inspect the surge protective device from different angles. For detailed technical specifications, electrical ratings and installation information, please refer to the other tabs.

Related Products

Type 2 DC Surge Protective Device TRS8
PV TRS8

Type 1+2 PV Surge Protective Device TRS8 1500v

Uocstc

1000v, 1250v

Ucpv

1200v, 1500

Iimp

5kA, 7kA

THOR TRSW-N coaxial surge protector with N-Male to N-Female connectors and a grounding lug, designed for 50 ohm RF lightning protection.
TRSW-N N/M to N/F

TRSW-N N-Type Coaxial Surge Arrester 50 Ohm Male to Female

Z0

50 Ohm

IL

≤0.3dB

Freq.

DC-2.5GHz

VSWR

<1.2

TRS3 DC SPD specification label showing Ucpv In Imax voltage protection level parameters
DC TRS3-C40

Type 2 DC Surge Protective Device TRS3-C40

Uocstc

110v, 24v, 48v, 75v

Ucpv

180v, 36v, 65v, 80v

Front view of Thor TRS30 B+C, a Type 1+2 AC surge protective device.
TRS30 B+C

Type 1+2 AC Surge Protective Device TRS30 B+C

Uc

275v

In

30kA

Imax

60kA

Iimp

4.5kA

Scroll to Top

Get In Touch