TRS-A50

Type 1 AC Surge Protective Device TRS-A50

Main Features

  • Maximum discharge current (8/20μs) Iimp: 50kA
  • Network Systems: TN-S, TT, TN-C-S
  • Mode of Protection: L-PE, N-PE
  • IEC/EN Category: Class I / Type 1
  • Protective Elements: High Energy MOV
  • Housing: Monobloc design
  • Application: Main Distribution Board
  • Compliance: EN 61643-11:2012, IEC 61643-11:2011/T1

CE certification ISO certification RoHS certification

The TRS-A Series is a Type 1 AC Surge Protective Device designed for service-entrance and main distribution boards. Using graphite-gap discharge technology, it provides high-energy lightning current handling capability and reliable protection against direct lightning strikes and severe transient overvoltages.

With a robust discharge structure, fast response, and stable performance, the TRS-A Series is suitable for residential, commercial, and industrial low-voltage power systems located in lightning-prone or surge-intensive environments.

The TRS-A50 is the high-performance model of the TRS-A SPD series, offering 50 kA (10/350 μs) impulse current capability for demanding electrical environments. It is designed for buildings equipped with external lightning protection systems (LPS) or installations exposed to frequent or severe lightning events.

Its high discharge capacity allows it to withstand strong direct lightning currents, making it suitable for large buildings, industrial plants, and critical electrical systems requiring maximum surge protection.

Applications

Buildings with LPS (external lightning rods)
Industrial plants and heavy-duty power systems
High lightning density regions
Main service entrance panels for large facilities

Model TRS-A15 TRS-A25 TRS-A50
Nominal volatge(Un) 230 V AC
Maximum operating voltage(Uc) 275 V AC
Lightning impulse current (10/350 μs)(Iimp) 15 kA 25 kA 50 kA
Voltage protection level(Up) ≤ 2,0 kV ≤ 2,2 kV ≤ 2,5 kV
Insulation resistance group > 100 mΩ
Response time <100ns
Cross-section of connected conductors solid (min/max) 16 mm2 / 35 mm2
Cross-section of connected conductors stranded (min/max) 16 mm2 / 35 mm2
Fault indication
Degree of protection IP20
Range of operating temperatures (min/max) -40℃~+70℃
Humidity range 5%~95%
Mounting DIN rail 35 mm
According to standard EN 61643-11:2012, IEC 61643-11:2011 / T1
Remarks Other Uc can be customized.(420V AC, 385V AC, 320V AC, etc.)

TRSA-Dimension

TRS-A Circuit diagram

Installation-Instruction-AC-SPD-TRS-A Installation-Instruction-AC-SPD-TRS-A

Related Products

Type 2 DC Surge Protective Device TRS8
PV TRS8

Type 1+2 PV Surge Protective Device TRS8 1500v

Uocstc

1000v, 1250v

Ucpv

1200v, 1500

Iimp

5kA, 7kA

THOR TRSW-N coaxial surge protector with N-Male to N-Female connectors and a grounding lug, designed for 50 ohm RF lightning protection.
TRSW-N N/M to N/F

TRSW-N N-Type Coaxial Surge Arrester 50 Ohm Male to Female

Z0

50 Ohm

IL

≤0.3dB

Freq.

DC-2.5GHz

VSWR

<1.2

Front view of Thor TRS3-C40, a DC surge protective device.
DC TRS3-C40

Type 2 DC Surge Protective Device TRS3-C40

Uocstc

110v, 24v, 48v, 75v

Ucpv

180v, 36v, 65v, 80v

Front view of Thor TRS30 B+C, a Type 1+2 AC surge protective device.
TRS30 B+C

Type 1+2 AC Surge Protective Device TRS30 B+C

Uc

275v

In

30kA

Imax

60kA

Iimp

4.5kA

Scroll to Top