TRS-C40

Type 2 AC Surge Protective Device TRS-C40

Main Features

  • Nominal discharge current (8/20μs) In: 20kA
  • Maximum discharge current (8/20μs) Imax: 40kA
  • Network Systems: TN-S, TT
  • Mode of Protection: L-PE, N-PE
  • IEC/EN Category: Class II / Type 2
  • Protective Elements: High Energy MOV
  • Housing: Pluggable design
  • Application: Sub-Distribution Board
  • Compliance: EN 61643-11:2012, IEC 61643-11:2011/T2

CE certification ISO certification RoHS certification

The TRS-C40 is a high-capacity Type 2 surge protective device designed to safeguard AC distribution networks exposed to stronger overvoltage stresses.
With 20 kA nominal and 40 kA maximum discharge capability, it provides robust MOV-based surge mitigation for medium-risk industrial and commercial electrical systems.

Designed for 230/275 V AC environments, the TRS-C40 offers a balanced combination of fast protection, stable clamping voltage, and long-term service reliability.
The modular pluggable design simplifies maintenance procedures, while the visual red fault indicator ensures clear monitoring without additional tools.

This model is ideal for installations requiring enhanced surge endurance, such as facilities with long cable runs or areas prone to induced lightning surges.

Applications

Industrial power networks with increased surge exposure
AC distribution boards in commercial facilities
Protection of machinery, HVAC equipment, and automation systems
Mid-level surge protection for main or sub-panels
Installations following Type 2 SPD requirements per EN 61643 standards

Model TRS-D10 TRS-D20 TRS-C40 TRS-B60 TRS-B80 TRS-B100
Nominal volatge (Un) 230 V AC
Maximum operating voltage (Uc) 275 V AC
Nominal discharge current (8/20μs)(In) 5 kA 10 kA 20 kA 30 kA 40 kA 60 kA
Maximum discharge current (8/20μs) (Imax) 10 kA 20 kA 40 kA 60 kA 80 kA 100 kA
Voltage protection level (Up) ≤ 0,7 kV ≤ 1,0 kV ≤ 1,3 kV ≤ 1,5 kV ≤ 1,8 kV ≤ 2,0 kV
Response time  (ta) < 25ns
Cross-section of connected conductors solid (min/max) 16 mm2 / 35 mm2
Cross-section of connected conductors stranded (min/max) 16 mm2 / 35 mm2
Fault indication red indication field
Degree of protection IP20
Range of operating temperatures (min/max) -40℃~+70℃
Humidity range 5%~95%
Mounting DIN rail 35 mm
According to standard EN 61643-11:2012, IEC 61643-11:2011 / T2
Remarks Other Uc can be customized.(420V AC, 385V AC, 320V AC, etc.)

TRS-B,C,D Dimension

TRS-B,C,D Circuit diagram

Installation Instruction AC SPD TRS-BCD Installation Instruction AC SPD TRS-BCD

Related Products

Type 2 DC Surge Protective Device TRS8
PV TRS8

Type 1+2 PV Surge Protective Device TRS8 1500v

Uocstc

1000v, 1250v

Ucpv

1200v, 1500

Iimp

5kA, 7kA

THOR TRSW-N coaxial surge protector with N-Male to N-Female connectors and a grounding lug, designed for 50 ohm RF lightning protection.
TRSW-N N/M to N/F

TRSW-N N-Type Coaxial Surge Arrester 50 Ohm Male to Female

Z0

50 Ohm

IL

≤0.3dB

Freq.

DC-2.5GHz

VSWR

<1.2

Front view of Thor TRS3-C40, a DC surge protective device.
DC TRS3-C40

Type 2 DC Surge Protective Device TRS3-C40

Uocstc

110v, 24v, 48v, 75v

Ucpv

180v, 36v, 65v, 80v

Front view of Thor TRS30 B+C, a Type 1+2 AC surge protective device.
TRS30 B+C

Type 1+2 AC Surge Protective Device TRS30 B+C

Uc

275v

In

30kA

Imax

60kA

Iimp

4.5kA

Scroll to Top