TRS-D20

Type 2 AC Surge Protective Device TRS-D20

Main Features

  • Nominal discharge current (8/20μs) In: 10kA
  • Maximum discharge current (8/20μs) Imax: 20kA
  • Network Systems: TN-S, TT
  • Mode of Protection: L-PE, N-PE
  • IEC/EN Category: Class II / Type 2
  • Protective Elements: High Energy MOV
  • Housing: Pluggable design
  • Application: Sub-Distribution Board
  • Compliance: EN 61643-11:2012, IEC 61643-11:2011/T2

CE certification ISO certification RoHS certification

The TRS-D20 is a durable Type 2 surge protector built for general-purpose AC power systems requiring improved surge handling.
Rated for 10 kA nominal and 20 kA maximum discharge current, it offers reliable MOV-based protection against switching surges and induced lightning overvoltages.

Its low protection level ensures stable performance with sensitive electrical equipment, while the fast <25 ns response time minimizes transient impact.
The pluggable cartridge design enables effortless module replacement without rewiring, and the built-in red status window provides immediate fault detection.

Engineered for 230 V / 275 V AC applications, the TRS-D20 is suitable for a wide range of industrial and commercial environments where consistent surge mitigation is essential.

Applications

Commercial and industrial power distribution panels
Protection of equipment exposed to moderate surge risk
AC distribution boards requiring 20 kA Type 2 SPD
Systems integrated with switching loads or automation devices
Installations requiring tool-free module replacement

Model TRS-D10 TRS-D20 TRS-C40 TRS-B60 TRS-B80 TRS-B100
Nominal volatge (Un) 230 V AC
Maximum operating voltage (Uc) 275 V AC
Nominal discharge current (8/20μs)(In) 5 kA 10 kA 20 kA 30 kA 40 kA 60 kA
Maximum discharge current (8/20μs) (Imax) 10 kA 20 kA 40 kA 60 kA 80 kA 100 kA
Voltage protection level (Up) ≤ 0,7 kV ≤ 1,0 kV ≤ 1,3 kV ≤ 1,5 kV ≤ 1,8 kV ≤ 2,0 kV
Response time  (ta) < 25ns
Cross-section of connected conductors solid (min/max) 16 mm2 / 35 mm2
Cross-section of connected conductors stranded (min/max) 16 mm2 / 35 mm2
Fault indication red indication field
Degree of protection IP20
Range of operating temperatures (min/max) -40℃~+70℃
Humidity range 5%~95%
Mounting DIN rail 35 mm
According to standard EN 61643-11:2012, IEC 61643-11:2011 / T2
Remarks Other Uc can be customized.(420V AC, 385V AC, 320V AC, etc.)

TRS-B,C,D Dimension

TRS-B,C,D Circuit diagram

Installation Instruction AC SPD TRS-BCD Installation Instruction AC SPD TRS-BCD

Related Products

Type 2 DC Surge Protective Device TRS8
PV TRS8

Type 1+2 PV Surge Protective Device TRS8 1500v

Uocstc

1000v, 1250v

Ucpv

1200v, 1500

Iimp

5kA, 7kA

THOR TRSW-N coaxial surge protector with N-Male to N-Female connectors and a grounding lug, designed for 50 ohm RF lightning protection.
TRSW-N N/M to N/F

TRSW-N N-Type Coaxial Surge Arrester 50 Ohm Male to Female

Z0

50 Ohm

IL

≤0.3dB

Freq.

DC-2.5GHz

VSWR

<1.2

Front view of Thor TRS3-C40, a DC surge protective device.
DC TRS3-C40

Type 2 DC Surge Protective Device TRS3-C40

Uocstc

110v, 24v, 48v, 75v

Ucpv

180v, 36v, 65v, 80v

Front view of Thor TRS30 B+C, a Type 1+2 AC surge protective device.
TRS30 B+C

Type 1+2 AC Surge Protective Device TRS30 B+C

Uc

275v

In

30kA

Imax

60kA

Iimp

4.5kA

Scroll to Top