TRS9-B100

Type 2 AC Surge Protective Device TRS9-B100

Main Features

  • Nominal discharge current (8/20μs) In: 60kA
  • Maximum discharge current (8/20μs) Imax: 100kA
  • Network Systems: TN-S, TT, TN-C-S
  • Mode of Protection: L-PE, N-PE
  • IEC/EN Category: Class II / Type 2
  • Protective Elements: High Energy MOV
  • Housing: Pluggable design
  • Application: Sub-Distribution Board
  • Compliance: EN 61643-11:2012, IEC 61643-11:2011/T2

CE certification ISO certification RoHS certification

The TRS9-B100 is designed as a robust Type 2 SPD for main distribution boards or high-load AC systems requiring strong surge-handling capability.
Delivering 60 kA nominal and 100 kA maximum discharge current, it offers reliable overvoltage limitation for environments where frequent switching surges or long external cabling elevate surge risks.

Its pluggable module allows fast tool-free replacement, while the front-mounted red fault indicator provides immediate status identification.
With stable voltage protection performance and rapid response characteristics, the TRS9-B100 ensures dependable protection for mission-critical circuits.

Applications

Main distribution boards in commercial or industrial facilities
Protection of essential loads such as pumps, HVAC equipment, and automation units
Installations with significant external cable exposure
Surge protection for medium-to-high energy environments
Systems requiring strong yet maintenance-friendly Type 2 SPD solutions

Parameter/Type TRS9-B80 TRS9-B100 TRS9-B120 TRS9-B150
Nominal volatge (Un) 380 V AC
Maximum operating voltage (Uc) 385 V AC
Nominal discharge current (8/20μs)( In) 40 kA 60 kA 80 kA 100 kA
Maximum discharge current (8/20μs) (Imax) 80 kA 100 kA 120 kA 150 kA
Voltage protection level (Up) ≤ 2,4 kV ≤ 2,5 kV ≤ 3,0 kV ≤ 3,5 kV
Response time (ta) < 25ns
Cross-section of connected conductors solid (min/max) 16 mm2 / 35 mm2
Cross-section of connected conductors stranded (min/max) 16 mm2 / 35 mm2
Fault indication red indication field
Remote indication potential-free change-over contact
Remote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DC
Cross-section of remote indication conductors 1,5 mm
Degree of protection IP20
Range of operating temperatures (min/max) -40℃~+70℃
Humidity range 5%~95%
Mounting DIN rail 35 mm
According to standard EN 61643-11:2012, IEC 61643-11:2011 / T2
Remarks Other Uc can be customized.(420V AC, 275V AC, 320V AC, etc.)

TRS9 Dimension

TRS9 Circuit Diagram

Installation Instruction AC SPD TRS9 Installation Instruction AC SPD TRS9

Related Products

Type 2 DC Surge Protective Device TRS8
PV TRS8

Type 1+2 PV Surge Protective Device TRS8 1500v

Uocstc

1000v, 1250v

Ucpv

1200v, 1500

Iimp

5kA, 7kA

THOR TRSW-N coaxial surge protector with N-Male to N-Female connectors and a grounding lug, designed for 50 ohm RF lightning protection.
TRSW-N N/M to N/F

TRSW-N N-Type Coaxial Surge Arrester 50 Ohm Male to Female

Z0

50 Ohm

IL

≤0.3dB

Freq.

DC-2.5GHz

VSWR

<1.2

Front view of Thor TRS3-C40, a DC surge protective device.
DC TRS3-C40

Type 2 DC Surge Protective Device TRS3-C40

Uocstc

110v, 24v, 48v, 75v

Ucpv

180v, 36v, 65v, 80v

Front view of Thor TRS30 B+C, a Type 1+2 AC surge protective device.
TRS30 B+C

Type 1+2 AC Surge Protective Device TRS30 B+C

Uc

275v

In

30kA

Imax

60kA

Iimp

4.5kA

Scroll to Top

Get In Touch