Type 1+2 AC Surge Protective Device TRS5 B+C
Main Features
- Lightning impulse current(10/350μs) In: 7kA/12.5kA
- Nominal discharge current (8/20μs) In: 20kA
- Maximum discharge current (8/20μs) Imax: 50kA
- Network Systems: TN-S, TT, TN-C-S
- Mode of Protection: L-PE, N-PE
- IEC/EN Category: Type 1+2 / Class I+II / Class B+C
- Protective Elements: High Energy MOV
- Housing: Pluggable design
- Application: Sub-Distribution Board
- Compliance: EN 61643-11:2012, IEC 61643-11:2011

The TRS5-B+C is a modular Type 1+2 surge protective device designed for applications requiring easy maintenance and fast module replacement.
Built with high-quality MOV components, the pluggable design enables technicians to replace protective cartridges without disconnecting wiring, reducing downtime and simplifying long-term system upkeep.
With a 7 kA (10/350 μs) impulse rating for lightning current and 50 kA maximum discharge capability, the TRS5 series offers dependable protection for residential and commercial power systems.
Its ≤1.3 kV voltage protection level efficiently limits transient overvoltages to safeguard sensitive downstream loads.
The device includes a clear red fault indicator and supports potential-free remote signaling, enhancing system visibility. Compact and easy to install on a 35 mm DIN rail, the TRS5-B+C is suitable for multi-unit buildings, commercial distribution panels, and installations with routine service requirements.
Applications
Residential and commercial sub-distribution boards
Buildings without external LPS or with moderate lightning exposure
Installations prioritizing quick replacement through pluggable cartridges
Electrical systems requiring simplified maintenance
Distribution panels for offices, retail locations, and small industrial units
| Model | TRS5-B+C |
| Nominal volatge (Un) | 230V AC |
| Maximum operating voltage (Uc) | 275V AC |
| Lightning impulse current(10/350μs) (limp) | 12,5kA |
| Nominal discharge current(8/20μs) (In) | 20kA |
| Maximum discharge current(8/20μs) (Imax) | 50kA |
| Voltage protection level (Up) | ≤1,3kV |
| Response time (ta) | <25ns |
| Cross-section of connected conductors solid(min/max) | 16mm²/35mm² |
| Cross-section of connected conductors stranded(min/max) | 16mm²/35mm² |
| Fault indication | red indication field |
| Remote indication | potential-free change-over contact |
| remote indication contacts | 250V/0,5A AC,250V/0,1A DC |
| Cross-section of remote indication conductors | 1,5mm² |
| Degree of protection | IP20 |
| Range of operating temperatures(min/max) | -40℃~+70℃ |
| Humidity range | 5%~95% |
| Mounting | DIN rail 35 mm |
| According to standard | EN61643-11:2012,IEC 61643-11:2011/T1+T2 |
| Remarks | Other Uc can be customized. (420VAC,385VAC,320VAC,etc.) |