PV TRS3-C40

Type 1+2 PV Surge Protective Device TRS3-C40

Main Features

  • Lightning impulse current(10/350μs) limp: 5kA/7kA
  • Nominal discharge current (8/20μs) In: 20kA
  • Maximum discharge current (8/20μs) Imax: 40kA
  • Network Systems: (+)-PE, (-)-PE, (+)-(-)
  • IEC/EN Category: Type 1+2 / Class I+II / Class B+C
  • Protective Elements: High Energy MOV
  • Housing: Pluggable design
  • Application: String box, Inverter
  • Compliance: EN 61643-31:2012, IEC 61643-31:2011

CE certification ISO certification RoHS certification TUV certification

The TRS3C-C40 Series is a specialized Type 1+2 DC surge protective device configured as a pluggable module for robust protection in Photovoltaic (PV) systems. It is engineered to handle the high energy of direct lightning currents and switching surges, delivering comprehensive defense for DC strings and central inverters.

Designed to accommodate modern solar installations, it operates across a wide voltage range, safely handling systems up to 1500 VDC. Its compact, pluggable-module structure features an integrated module locking mechanism, ensuring reliability and simplifying maintenance without compromising security.

Equipped with high-performance protective components, the TRS3C-C40 provides superior defense against high-energy transients, evidenced by its significant lightning current handling capability. It is designed with a high short-circuit current rating ($I_{scpv}$), a key safety feature that maintains system integrity.

A clear visual fault indicator provides instant status feedback. Furthermore, optional potential-free remote signaling contacts allow seamless integration with monitoring systems for real-time fault reporting. Its DIN-rail mounting and robust enclosure design enable fast, secure installation inside combiner boxes and DC distribution enclosures.

Engineered for demanding renewable-energy environments, the TRS3C-C40 performs reliably across a wide temperature and humidity range, ensuring long-term stability in utility-scale solar farms and commercial installations requiring top-tier T1+T2 protection.

Applications

DC string protection for utility-scale and commercial PV systems requiring robust T1+T2 defense.
Solar combiner boxes, main DC distribution panels, and protection upstream of high-value inverters.
PV installations that are without an external Lightning Protection System (LPS) or where separation distance cannot be maintained.
High-voltage PV arrays up to 1500 VDC, including modern large-scale deployments.
Systems requiring visual fault indication and optional remote alarm integration, combined with enhanced operational safety.

Parameter/Type TRS3-C40
PV connection type Y
Nominal PV Voltage   Uocstc 1000V DC 1250V DC
Max. PV Operating Voltage   Ucpv 1200V DC 1500V DC
Lightning impulse current(10/350μs)   Iimp 7kA 5kA
Nominal discharge current (8/20μs)   In 20kA
Maximum discharge current (8/20μs)   Imax 40kA
Voltage protection level mode +/PE, -/PE   Up ≤4.5kV ≤5.0kV
Short-circuit current rating   Iscpv 100A
Response time   ta <25ns
Cross-section of connected conductors solid(min/max) 16mm²/35mm²
Cross-section of connected conductors stranded(min/max) 16mm²/35mm²
Fault indication red indication field
Remote indication potential-free change-over contact
Remote indication contacts 250V/0.5A AC, 250V/0.1A DC
Cross-section of remote indication conductors 1.5mm²
Degree of protection IP20
Range of operating temperatures (min/max) -40°C~+70°C
Humidity range 5%~95%
Mounting DIN rail 35 mm
According to standard EN 61643-31:2012, IEC 61643-31:2011/T1+T2
Remarks Other UCPV can be customized. (1200VDC, 1500VDC, etc.)

TRS8 Dimension

TRS8 Circuit Diagram

Installation Instruction AC SPD TRS3Installation Instruction AC SPD TRS3

Related Products

Type 2 DC Surge Protective Device TRS8
PV TRS8

Type 1+2 PV Surge Protective Device TRS8 1500v

Uocstc

1000v, 1250v

Ucpv

1200v, 1500

Iimp

5kA, 7kA

THOR TRSW-N coaxial surge protector with N-Male to N-Female connectors and a grounding lug, designed for 50 ohm RF lightning protection.
TRSW-N N/M to N/F

TRSW-N N-Type Coaxial Surge Arrester 50 Ohm Male to Female

Z0

50 Ohm

IL

≤0.3dB

Freq.

DC-2.5GHz

VSWR

<1.2

Front view of Thor TRS3-C40, a DC surge protective device.
DC TRS3-C40

Type 2 DC Surge Protective Device TRS3-C40

Uocstc

110v, 24v, 48v, 75v

Ucpv

180v, 36v, 65v, 80v

Front view of Thor TRS30 B+C, a Type 1+2 AC surge protective device.
TRS30 B+C

Type 1+2 AC Surge Protective Device TRS30 B+C

Uc

275v

In

30kA

Imax

60kA

Iimp

4.5kA

Scroll to Top