TRS2-D20

Type 2 AC Surge Protective Device TRS2-D20

Main Features

  • Nominal discharge current (8/20μs) In: 10kA
  • Maximum discharge current (8/20μs) Imax: 20kA
  • Network Systems: TN-S, TT
  • Mode of Protection: L-PE, N-PE
  • IEC/EN Category: Class II / Type 2
  • Protective Elements: High Energy MOV
  • Housing: Pluggable design
  • Application: Sub-Distribution Board
  • Compliance: EN 61643-11:2012, IEC 61643-11:2011/T2

CE certification ISO certification RoHS certificationTUV certification

The TRS2-D20 is a compact Type 2 surge protective device engineered for AC sub-distribution systems requiring dependable mid-level surge suppression.
Using high-quality MOV technology, it provides 10 kA nominal and 20 kA maximum discharge capability, ensuring stable protection against switching surges and induced lightning overvoltages within 230 V AC networks.

Its pluggable module design allows fast and convenient replacement without service interruption, while the built-in visual red fault indicator offers immediate status recognition.
Designed for standard indoor electrical panels, the TRS2-D20 features a slim 2P/4P configuration to fit compact distribution spaces and supports optional remote signalling for integration into monitoring systems.

With fast response time and a robust operating temperature range, it is a reliable choice for residential, commercial, and light industrial power installations that require consistent Type 2 surge protection.

Applications

Residential and commercial AC distribution panels
Secondary protection for terminal equipment and control devices
Sub-distribution boards where compact Type 2 SPD is required
Installations using automation loads or switching circuits
Systems requiring optional remote signalling for fault monitoring

Model TRS2-D20 TRS2-C40
Nominal volatge (Un) 230 V AC
Maximum operating voltage (Uc) 275 V AC
Nominal discharge current (8/20μs)( In) 10 kA 20 kA
Maximum discharge current (8/20μs) (Imax) 20 kA 40 kA
Voltage protection level (Up) ≤ 1,0 kV ≤ 1,3 kV
Response time (ta) < 25ns
Cross-section of connected conductors solid (min/max) 16 mm2 / 35 mm2
Cross-section of connected conductors stranded (min/max) 16 mm2 / 35 mm2
Fault indication red indication field
Remote indication potential-free change-over contact
Remote indication contacts 250 V / 0,5 A AC, 250 V / 0,1 A DC
Cross-section of remote indication conductors 1,5 mm
Degree of protection IP20
Range of operating temperatures (min/max) -40℃~+70℃
Humidity range 5%~95%
Mounting DIN rail 35 mm
According to standard EN 61643-11:2012, IEC 61643-11:2011 / T2
Remarks Other Uc can be customized.(420V AC, 385V AC, 320V AC, etc.

 

TRS2 Dimension

TRS2 Circuit diagram

Installation Instruction AC SPD TRS2 Installation Instruction AC SPD TRS2

Rotate the 3D model to inspect the surge protective device from different angles. For detailed technical specifications, electrical ratings and installation information, please refer to the other tabs.

Related Products

Type 2 DC Surge Protective Device TRS8
PV TRS8

Type 1+2 PV Surge Protective Device TRS8 1500v

Uocstc

1000v, 1250v

Ucpv

1200v, 1500

Iimp

5kA, 7kA

THOR TRSW-N coaxial surge protector with N-Male to N-Female connectors and a grounding lug, designed for 50 ohm RF lightning protection.
TRSW-N N/M to N/F

TRSW-N N-Type Coaxial Surge Arrester 50 Ohm Male to Female

Z0

50 Ohm

IL

≤0.3dB

Freq.

DC-2.5GHz

VSWR

<1.2

TRS3 DC SPD specification label showing Ucpv In Imax voltage protection level parameters
DC TRS3-C40

Type 2 DC Surge Protective Device TRS3-C40

Uocstc

110v, 24v, 48v, 75v

Ucpv

180v, 36v, 65v, 80v

Front view of Thor TRS30 B+C, a Type 1+2 AC surge protective device.
TRS30 B+C

Type 1+2 AC Surge Protective Device TRS30 B+C

Uc

275v

In

30kA

Imax

60kA

Iimp

4.5kA

Scroll to Top